The torque of the electric power meter is related to the mutual direction of the voltage of the meter and the current coil. If the current direction of one of the coils is reversed, the torque will change direction. At this time, not only the reading but also the pointer will be hit. Bend. In order to prevent this, the “*” or “+” and “-” signs are marked next to the power terminal terminals. When wiring the power meter, the “*” terminals of the current and voltage coils should be connected to the same Polarity, to ensure that the current direction of the two coils is consistent, and from "+" to "-", this is the so-called "generator end code" of the power meter wiring.

There is also the possibility of pointer reversal when measuring with the power meter properly wired. There are two reasons for this. The first is that there is actually a Power Supply on the load side, and the load branch does not consume power but emits power: the second possibility may occur in the power measurement of the three-phase circuit, and for the load with cosφ < 0.5, the two are connected to the three phases. The power meter of the circuit must have a negative reading. In order to obtain the reading, the polarity of the voltage or current should be reversed. The polarity switch can switch the polarity switch position and add a negative in front of the reading. number.

Therefore, when measuring single-phase power, when the meter is reversed, one coil of the meter is reversed, and the measurement result can be added with a minus sign. When measuring the most three-phase power, when one power meter is reversed, the three-phase power should be two. The difference between the tables, this should be very careful.

Printer Adapter

Printer Adapter means the charger of printer; the most printers used in the market are HP, EPSON, CANON and BROTHER brands, yidashun produces ac adapter for all these brands of printers. The output voltage of these printer ac adapters are normally 12V, 16V, 22V, 24V, 30V, 32V and so on, the common dc plugs are 3 hole (Flat) and 3 pin (Round).


The popular hp printer adapters are double output 32V 1.1A/ 16V 1.6A, 16V 625mA / 32V 940mA, 12V 250mA /32V 1094mA, and single output 30V 333mA, 32V 2000mA, 32V 2500mA, 22V 455mA and 32V 625mA, the dc plug of all these models are 3 hole (Flat). The popular EPSON printer charger is 24V 2A output with 3 pin (round) dc plug.

printer adapter power supply

printer adapter power supply

printer adapter power supply

Printer Adapter,Bluetooth Printer Adapter,Wireless Printer Adapter,Wifi Printer Adapter

Shenzhen Yidashun Technology Co., Ltd. , https://www.ydsadapter.com